The short answer
Check that the linked file still exists on the expected volume and was finalized. Metadata can remain after a disk is disconnected or a file is removed.
Work through the checks
Match an event entry to the camera, timestamp and any linked local media. An event is metadata; its presence does not guarantee that a complete video clip was saved.
Check the actual recording volume, available space and write permission. Confirm the folder belongs to the intended disk rather than an unavailable USB drive or a redirected system folder.
If recording is available in the installed build, capture a short authorized test event. Confirm a new local file is created, grows as expected and can be reopened after recording stops.
Read the codec for the selected camera profile rather than inferring it from resolution or filename. Test a documented baseline stream without changing every encoding option at once.
What to verify
Reopen a completed test clip and seek to a known event time if the player permits seeking. Confirm moving images, duration and camera identity; a thumbnail or event row alone is insufficient.
Sources and scope
AeoCam is available for Windows. Camera settings below describe protocol preparation, not a certification of a particular camera or a promise of every feature in every app version. Check the installed build and the Microsoft Store listing for current availability.
Vendor documents describe the camera or protocol. No physical-camera compatibility test is claimed here. Menus and capabilities can change with model and firmware.